2
2
mirror of https://github.com/octoleo/restic.git synced 2024-11-30 08:44:02 +00:00
Commit Graph

57 Commits

Author SHA1 Message Date
Michael Eischer
ad48751adb bump required go version to 1.21 2024-08-10 19:16:10 +02:00
Alexander Neumann
c0514dd8ba Fix linter errors (except for tests) 2024-02-10 22:58:10 +01:00
Michael Eischer
bd883caae1 CI: enable bodyclose linter 2024-01-19 21:17:18 +01:00
Michael Eischer
1b8a67fe76 move Backend interface to backend package 2023-10-25 23:00:18 +02:00
Michael Eischer
7881309d63 backend: move backend implementation helpers to util package
This removes code that is only used within a backend implementation from
the backend package. The latter now only contains code that also has
external users.
2023-10-25 22:54:07 +02:00
Michael Eischer
50e0d5e6b5 backend: Hardcode backend scheme in Factory
Our ParseConfig implementations always expect a specific scheme, thus no
other scheme would work.
2023-06-17 15:15:58 +02:00
Michael Eischer
13a8b5822f backend: Adjust tests to use the Factory to instantiate the backend
This drastically reduces the amount of duplicated test code.
2023-06-17 15:15:58 +02:00
Michael Eischer
7d12c29286 backend: Unify backend construction using factory and registry
This unified construction removes most backend-specific code from
global.go. The backend registry will also enable integration tests to
use custom backends if necessary.
2023-06-17 15:15:57 +02:00
Michael Eischer
56836364a4 backend: pass context into every backend constructor 2023-06-17 15:15:57 +02:00
Michael Eischer
f903db492c backend: let ParseConfig return a Config pointer
In order to change the backend initialization in `global.go` to be able
to generically call cfg.ApplyEnvironment() for supported backends, the
`interface{}` returned by `ParseConfig` must contain a pointer to the
configuration.

An alternative would be to use reflection to convert the type from
`interface{}(Config)` to `interface{}(*Config)` (from value to pointer
type). However, this would just complicate the type mess further.
2023-06-07 22:31:15 +02:00
Michael Eischer
25a0be7f26 backend: fix linter warnings 2023-06-07 22:31:15 +02:00
Michael Eischer
a27b7f1370 backend: use generic instead of any type for test suite 2023-06-07 22:31:14 +02:00
Michael Eischer
fa361dbfbd backend: use generic implementation for ParseConfig tests 2023-06-07 22:30:35 +02:00
Michael Eischer
5260d38980 backend: let ParseConfig return concrete type 2023-06-07 22:30:35 +02:00
greatroar
f90bf84ba7 test: Use testing.T.Cleanup to remove tempdirs 2022-12-09 14:23:55 +01:00
Michael Eischer
f3d964a8c1 rclone: treat "file already closed" as command startup error
Since #3940 the rclone backend returns the commands exit code if it
fails to start. The list of expected errors was missing the "file
already closed"-error which can occur if the http test request first
learns about the closed pipe to rclone before noticing the canceled
context.

Go internally makes sure that a file descriptor is unusable once it was
closed, thus this cannot have unintended side effects (like accidentally
reading from the wrong file due to a reused file descriptor).
2022-12-02 20:46:02 +01:00
greatroar
d4aadfa389 all: Drop ctxhttp
This package is no longer needed, since we can use the stdlib's
http.NewRequestWithContext.

backend/rclone already did, but it needed a different error check due to
a difference between net/http and ctxhttp.

Also, store the http.Client by value in the REST backend (changed to a
pointer when ctxhttp was introduced) and use errors.WithStack instead
of errors.Wrap where the message was no longer accurate. Errors from
http.NewRequestWithContext will start with "net/http" or "net/url", so
they're easy to identify.
2022-10-14 14:33:49 +02:00
Michael Eischer
5600f11696 rclone: Fix stderr handling if command exits unexpectedly
According to the documentation of exec.Cmd Wait() must not be called
before completing all reads from the pipe returned by StdErrPipe(). Thus
return a context that is canceled once rclone has exited and use that as
a precondition to calling Wait(). This should ensure that all errors
printed to stderr have been copied first.
2022-10-08 20:16:06 +02:00
Michael Eischer
b8acad4da0 rclone: return rclone error instead of canceled context
When rclone fails during the connection setup this currently often
results in a context canceled error. Replace this error with the exit
code from rclone.
2022-10-08 20:15:24 +02:00
Leo R. Lundgren
ebe9f2c969 rclone/sftp: Improve handling of ErrDot errors
Restic now yields a more informative error message when exec.ErrDot occurs.
2022-09-25 16:19:03 +02:00
Michael Eischer
506d92e87c rclone: Return a permanent error if rclone already exited
rclone can exit early for example when the connection to rclone is
relayed for example via ssh: `-o rclone.program='ssh user@example.org
forced-command'`
2022-08-23 22:05:04 +02:00
Michael Eischer
a0cef9f247 limiter: move to internal/backend 2022-07-17 13:40:15 +02:00
greatroar
f92ecf13c9 all: Move away from pkg/errors, easy cases
github.com/pkg/errors is no longer getting updates, because Go 1.13
went with the more flexible errors.{As,Is} function. Use those instead:
errors from pkg/errors already support the Unwrap interface used by 1.13
error handling. Also:

* check for io.EOF with a straight ==. That value should not be wrapped,
  and the chunker (whose error is checked in the cases changed) does not
  wrap it.
* Give custom Error methods pointer receivers, so there's no ambiguity
  when type-switching since the value type will no longer implement error.
* Make restic.ErrAlreadyLocked private, and rename it to
  alreadyLockedError to match the stdlib convention that error type
  names end in Error.
* Same with rest.ErrIsNotExist => rest.notExistError.
* Make s3.Backend.IsAccessDenied a private function.
2022-06-14 08:36:38 +02:00
Michael Eischer
b0e64deb27 rclone: Fix timeout calculation 2021-11-07 17:49:33 +01:00
phcreery
43d173b042 rclone: add timeout option and documentation 2021-11-07 17:49:21 +01:00
greatroar
950b818274 rclone: Return one fewer value from run 2021-08-26 18:12:08 +02:00
greatroar
fa3eed1998 Use rclone.wrappedConn by pointer
This shaves a kilobyte off the Linux binary by not generating a
non-pointer interface implementation.
2021-08-01 09:11:50 +02:00
Alexander Neumann
f867e65bcd Fix issues reported by staticcheck 2021-01-30 20:43:53 +01:00
Alexander Neumann
aef3658a5f Address review comments 2021-01-30 20:02:37 +01:00
Alexander Neumann
3c753c071c errcheck: More error handling 2021-01-30 20:02:37 +01:00
tofran
94a154c7ca Remove --drive-use-trash=false from rclone param
Google drive trash retention policy changed making this
no longer a good default
a go
Issue #3095
2020-11-13 22:58:48 +00:00
Michael Eischer
37a5e2d681 rest: use global context on repository creation 2020-10-09 22:39:06 +02:00
Michael Eischer
8c36317b71 rclone: use configured number of connections during create 2020-09-19 19:11:43 +02:00
Michael Eischer
60a5c35de9 rclone: close connection to rclone if open fails 2020-09-19 19:11:43 +02:00
aawsome
0fed6a8dfc
Use "pack file" instead of "data file" (#2885)
- changed variable names, especially changed DataFile into PackFile
- changed in some comments
- always use "pack file" in docu
2020-08-16 11:16:38 +02:00
Michael Eischer
c81b122374 rclone: Don't panic after unexpected subprocess exit
As the connection to the rclone child process is now closed after an
unexpected subprocess exit, later requests will cause the http2
transport to try to reestablish a new connection. As previously this never
should have happened, the connection called panic in that case. This
panic is now replaced with a simple error message, as it no longer
indicates an internal problem.
2020-08-01 12:17:40 +02:00
Michael Eischer
ea97ff1ba4 rclone: Skip crash test when rclone is not found 2020-07-26 12:06:18 +02:00
Michael Eischer
01b9581453 rclone: Better field names for stdio conn 2020-07-26 00:29:25 +02:00
Michael Eischer
3cd927d180 rclone: Give rclone time to finish before closing stdin pipe
Calling `Close()` on the rclone backend sometimes failed during test
execution with 'signal: Broken pipe'. The stdio connection closed both
the stdin and stdout file descriptors at the same moment, therefore
giving rclone no chance to properly send any final http2 data frames.

Now the stdin connection to rclone is closed first and will only be
forcefully closed after a timeout. In case rclone exits before the
timeout then the stdio connection will be closed normally.
2020-07-26 00:29:25 +02:00
greatroar
bf7b1f12ea rclone: Add test for pipe handling when rclone exits 2020-07-26 00:29:25 +02:00
Michael Eischer
8554332894 rclone: Close rclone side of stdio_conn pipes
restic did not notice when the rclone subprocess exited unexpectedly.

restic manually created pipes for stdin and stdout and used these for the
connection to the rclone subprocess. The process creating a pipe gets
file descriptors for the sender and receiver side of a pipe and passes
them on to the subprocess. The expected behavior would be that reads or
writes in the parent process fail / return once the child process dies
as a pipe would now just have a reader or writer but not both.

However, this never happened as restic kept the reader and writer
file descriptors of the pipes. `cmd.StdinPipe` and `cmd.StdoutPipe`
close the subprocess side of pipes once the child process was started
and close the parent process side of pipes once wait has finished. We
can't use these functions as we need access to the raw `os.File` so just
replicate that behavior.
2020-07-26 00:29:25 +02:00
greatroar
3e93b36ca4 Make rclone.New private 2020-07-26 00:28:45 +02:00
Alexander Neumann
99fd80a585 Remove all workarounds for Go < 1.11 2020-02-26 20:35:13 +01:00
Alexander Neumann
3865b59716 rclone: Rework backend option parsing
This change allows passing no arguments to rclone, using `-o
rclone.args=""`. It is helpful when running rclone remotely via SSH
using a key with a forced command (via `command=` in `authorized_keys`).
2019-03-02 10:36:42 +01:00
Alexander Neumann
7ac683c360 rclone: Inject debug logger for HTTP 2018-10-21 19:58:40 +02:00
Alexander Neumann
bfd923e81e rclone: Respect bandwith limits 2018-05-22 20:48:17 +02:00
Alexander Neumann
3f48e0e0f4 Add extra options to rclone
For details see https://github.com/restic/restic/pull/1657#issuecomment-377707486
2018-04-01 10:34:30 +02:00
Alexander Neumann
86f4b03730 Remove unneeded byte counters 2018-04-01 10:18:38 +02:00
Alexander Neumann
c43c94776b rclone: Make concurrent connections configurable 2018-04-01 10:18:38 +02:00
Alexander Neumann
0b776e63e7 backend/rclone: Request random file name
When `/` is requested, rclone returns the list of all files in the
remote, which is not what we want (and it can take quite some time).
2018-04-01 10:18:38 +02:00