When restic reads the backup from stdin, the number of bytes processed
was always displayed as zero. The reason is that the UI for the archive
uses the total bytes as returned by the scanner, which is zero for
stdin. So instead we keep track of the real number of bytes processed
and print that at the end.
Closes #2136
don't create fileInfo structs for empty files. this saves memory.
this also avoids extra serial scan of all fileInfo, which should
make restore faster and more consistent.
Signed-off-by: Igor Fedorenko <igor@ifedorenko.com>
reworked restore error callback to use file location
path instead of much heavier Node. this reduced restore
memory usage by as much as 50% in some of my tests.
Signed-off-by: Igor Fedorenko <igor@ifedorenko.com>
* uses less memory as common prefix is only stored once
* stepping stone for simpler error callback api, which
will allow further memory footprint reduction
Signed-off-by: Igor Fedorenko <igor@ifedorenko.com>
When the scanner is slower than the actual backup, the tomb cancels the
context passed to Scan(), which then returns ctx.Err(). In the end, the
main function prints an error message that is not helpful ("Context
cancelled") and exits with an error code although no error occurred.
The code now ignores the error in the context and just uses it for
cancellation. The scanner is not supposed to return an error anyway.
Closes #1978
Sometimes, users run restic without retaining the local cache
directories. This was reported several times in the past.
Restic will now print a message whenever a new cache directory is
created from scratch (i.e. it did not exist before), so users have a
chance to recognize when the cache is not kept between different runs of
restic.
This commit adds a command called `self-update` which downloads the
latest released version of restic from GitHub and replacing the current
binary with it. It does not rely on any external program (so it'll work
everywhere), but still verifies the GPG signature using the embedded GPG
public key.
By default, the `self-update` command is hidden behind the `selfupdate`
built tag, which is only set when restic is built using `build.go`. The
reason for this is that downstream distributions will then not include
the command by default, so users are encouraged to use the
platform-specific distribution mechanism.
Adds a SelectByName method to the archive and scanner which only require
the filename as input, and can thus be run before calling lstat on the
file. Can speed up scanning significantly if a lot of filename excludes
are used.
Accessing beyond the end of the file now removes the file from the cache
because it is assumed to be truncated. Usually, this means that the data
is fetched directly from the backend instead.