This turns snapshotFilterOptions from cmd into a restic.SnapshotFilter
type and makes restic.FindFilteredSnapshot and FindFilteredSnapshots
methods on that type. This fixes #4211 by ensuring that hosts and paths
are named struct fields instead of unnamed function arguments in long
lists of such.
Timestamp limits are also included in the new type. To avoid too much
pointer handling, the convention is that time zero means no limit.
That's January 1st, year 1, 00:00 UTC, which is so unlikely a date that
we can sacrifice it for simpler code.
TestRepository and its variants always returned no-op cleanup functions.
If they ever do need to do cleanup, using testing.T.Cleanup is easier
than passing these functions around.
Hard links to the same file now get the same inode within the FUSE
mount. Also, inode generation is faster and, more importantly, no longer
allocates.
Benchmarked on Linux/amd64. Old means the benchmark with
sink = fs.GenerateDynamicInode(1, sub.node.Name)
instead of calling inodeFromNode. Results:
name old time/op new time/op delta
Inode/no_hard_links-8 137ns ± 4% 34ns ± 1% -75.20% (p=0.000 n=10+10)
Inode/hard_link-8 33.6ns ± 1% 9.5ns ± 0% -71.82% (p=0.000 n=9+8)
name old alloc/op new alloc/op delta
Inode/no_hard_links-8 48.0B ± 0% 0.0B -100.00% (p=0.000 n=10+10)
Inode/hard_link-8 0.00B 0.00B ~ (all equal)
name old allocs/op new allocs/op delta
Inode/no_hard_links-8 1.00 ± 0% 0.00 -100.00% (p=0.000 n=10+10)
Inode/hard_link-8 0.00 0.00 ~ (all equal)
We previously checked whether the set of snapshots might have changed
based only on their number, which fails when as many snapshots are
forgotten as are added. Check for the SHA-256 of their id's instead.
FindFilteredSnapshots no longer prints errors during snapshot loading on
stderr, but instead passes the error to the callback to allow the caller
to decide on what to do.
In addition, it moves the logic to handle an explicit snapshot list from
the main package to restic.
bazil/fuse expects us to return context.Canceled to signal that a
syscall was successfully interrupted. Returning a wrapped version of
that error however causes the fuse library to signal an EIO (input/output
error). Thus unwrap context.Canceled errors before returning them.
Cleanly separate the directory presentation and the snapshot directory
structure. SnapshotsDir now translates the dirStruct into a format
usable by the fuse library and contains only minimal special case rules.
All decisions have moved into SnapshotsDirStructure which now creates a
fully preassembled tree data structure.
These commands filter the snapshots according to some criteria which
essentially requires loading the index before filtering the snapshots.
Thus create a copy of the snapshots list beforehand and use it later on.
In #2584 this was changed to use the uid/gid of the root node. This
would be okay for the top-level directory of a snapshot, however, this
change also applied to normal directories within a snapshot. This
change reverts the problematic part and adds a test that directory
attributes are represented correctly.
- Add Open() functionality to dir
- only access index for blobs when file is read
- Implement NodeOpener and put one-time file stuff there
- Add comment about locking as suggested by bazil.org/fuse
=> Thanks at Michael Eischer for suggesting the last two improvements
This command can only be built on Darwin, FreeBSD and Linux
(and if we upgrade bazil.org/fuse, only FreeBSD and Linux:
https://github.com/bazil/fuse/issues/224).
Listing the few supported operating systems explicitly here makes
porting restic to new platforms easier.
The `dump`, `find`, `forget`, `ls`, `mount`, `restore`, `snapshots`,
`stats` and `tag` commands will now take into account multiple
`--host` and `-H` flags.
When looking up a blob in the master index, with several
indexes present in the master index, a significant amount of time
is spent generating errors for each failed lookup. However, these
errors are often used to check if a blob is present, but the contents
are not inspected making the overhead of the error not useful.
Instead, change Index.Lookup (and Index.LookupSize) to instead return
a boolean denoting if the blob was found instead of an error. Also change
all the calls to these functions to handle the new function signature.
benchmark old ns/op new ns/op delta
BenchmarkMasterIndexLookupSingleIndex-6 820 897 +9.39%
BenchmarkMasterIndexLookupMultipleIndex-6 12821 2001 -84.39%
BenchmarkMasterIndexLookupSingleIndexUnknown-6 5378 492 -90.85%
BenchmarkMasterIndexLookupMultipleIndexUnknown-6 17026 1649 -90.31%
benchmark old allocs new allocs delta
BenchmarkMasterIndexLookupSingleIndex-6 9 9 +0.00%
BenchmarkMasterIndexLookupMultipleIndex-6 59 19 -67.80%
BenchmarkMasterIndexLookupSingleIndexUnknown-6 22 6 -72.73%
BenchmarkMasterIndexLookupMultipleIndexUnknown-6 72 16 -77.78%
benchmark old bytes new bytes delta
BenchmarkMasterIndexLookupSingleIndex-6 160 160 +0.00%
BenchmarkMasterIndexLookupMultipleIndex-6 3200 240 -92.50%
BenchmarkMasterIndexLookupSingleIndexUnknown-6 1232 48 -96.10%