The old behavior was problematic in the context of rebuild-index as it
could leave old, possibly invalid index files behind without returning a
fatal error.
Prune calls rebuildIndex before removing any data from the repository.
For this use case failing to delete an old index MUST be treated as a
fatal error. Otherwise the index could still contain an old index file
that refers to blobs/packs that were later on deleted by prune. Later
backup runs will assume that the affected blobs already exist in the
repository which results in a backup which misses data.
The previous check only approximately verified whether all required
blobs were found. However, after forgetting a few snapshots the
repository contains lots of unused blobs whose number can be sufficient
to make up for missing packs.
When coupled with a malfunctioning backend that temporarily returns broken
data this could cause restic to regard the corresponding packs as
invalid and thereby delete data that's still in use. This change lets
restic play it safe and refuse to delete anything if data is missing.
Do not lock the repository if --no-lock global flag is set. This allows
to mount repositories which are archived on a read only system.
Signed-off-by: Sébastien Gross <seb•ɑƬ•chezwam•ɖɵʈ•org>
The seen BlobSet always contained a subset of the entries in blobs.
Thus use blobs instead and avoid the memory overhead of the second set.
Suggested-by: Alexander Weiss <alex@weissfam.de>
As the connection to the rclone child process is now closed after an
unexpected subprocess exit, later requests will cause the http2
transport to try to reestablish a new connection. As previously this never
should have happened, the connection called panic in that case. This
panic is now replaced with a simple error message, as it no longer
indicates an internal problem.
- Add Open() functionality to dir
- only access index for blobs when file is read
- Implement NodeOpener and put one-time file stuff there
- Add comment about locking as suggested by bazil.org/fuse
=> Thanks at Michael Eischer for suggesting the last two improvements
Calling `Close()` on the rclone backend sometimes failed during test
execution with 'signal: Broken pipe'. The stdio connection closed both
the stdin and stdout file descriptors at the same moment, therefore
giving rclone no chance to properly send any final http2 data frames.
Now the stdin connection to rclone is closed first and will only be
forcefully closed after a timeout. In case rclone exits before the
timeout then the stdio connection will be closed normally.
restic did not notice when the rclone subprocess exited unexpectedly.
restic manually created pipes for stdin and stdout and used these for the
connection to the rclone subprocess. The process creating a pipe gets
file descriptors for the sender and receiver side of a pipe and passes
them on to the subprocess. The expected behavior would be that reads or
writes in the parent process fail / return once the child process dies
as a pipe would now just have a reader or writer but not both.
However, this never happened as restic kept the reader and writer
file descriptors of the pipes. `cmd.StdinPipe` and `cmd.StdoutPipe`
close the subprocess side of pipes once the child process was started
and close the parent process side of pipes once wait has finished. We
can't use these functions as we need access to the raw `os.File` so just
replicate that behavior.