--browser-only assumes syncthing is already running and will open the
user's browser in the URL:port currently used in the configuration if
the GUI is enabled.
Every time a JSON object is returned in an HTTP response, the
appropriate header needs to be set and the object itself needs to be
encoded. Doing this in every function is repetitive and error prone
(getDBFile and postDBScan, for instance, never set any headers).
This adds a helper function to centralize the appropriate JSON response
handling.
PR #2578 enables us to remove the exit code 2 from the list of
success status codes, because SIGINT will be handled properly.
I have also converted STNORESTART to --no-restart for the sake
of consistency.
With this change, the behavior is as follows:
- SIGTERM / SIGINT: Exit cleanly (exit code 0)
- SIGHUP: Restart
This is the case both when hitting the monitor process or the inner
process, or if running with NORESTART (but then we won't restart,
obviously, just exit with code exitRestarting).
It enables "pkill -HUP syncthing" to do the right thing to restart all
Syncthings on package upgrade, for example.
Previously, when unmarshing the SOAP error code data we would overwrite
the original err, typically with null since the parsing of the error
code information succeeds. If we don't have a upnp 725 error, we would fall
back to returning null or no error. This broke our upnp error handling
logic for AddPortMappings as it would think it succeeds if it gets a 718
permission error.
Also fixes what I think migh thave been a bug where we did not use the
proxy for usage reports. And removes the BuildEnv field that we don't
need any more.
This is the same issue as #2014/#2062. Bootstrap doesn't like having two dialogs
open at once: it marks the body has having no dialogs open when the first dialog
is closed, regardless of whether the second dialog is still open.
This means that scrolling doesn't happen properly, and the user cannot
scroll to the dialog's 'close' button.
Work around this by making sure the first dialog (the settings page) is fully closed
before the second dialog (usage preview) is opened.